Pyramid 7000 with 110V output
Lathem Sonachron Replacement Timer


Replaces Lathem Sonachron. Additional feature: Variable duration rings, use for "two minute warnings" of end of break, end of lunch. 110V output. Ships wired & tested. EASIEST SETUP ON THE MARKET.


Our Price: $389.00
 
 
110V Pyramid 7000

Accessories & Supplies:

DetailsIDProduct NameDescriptionPriceAdd To Cart
Click 115 Surge ProtectorPower surges are not covered w/o surge protection$14.95
Click 233 Manual Ring ButtonRing Button$45.00
Click 407 Bell Wire25' Insulated bell wire$19.95
Click 404 Bell Wire50' Insulated bell wire$34.95
Click 405 Bell Wire100' Insulated bell wire$44.95
Click 413 Bell Wire250' Insulated bell wire$94.95
Click 86 4" 120V AC Buzzer 102dB4" 120V Indoor Buzzer$139.00
Click 88 6" 110V AC Bell 96 > 102dB6" 110V Indoor Bell$89.00
Click 78 Amber Strobe Light 110VACStrobe Light$74.99
Click 93 BCD Cable 50'Master Clock Signal Cable$19.95
Click 94 BCD Cable 100'Master Clock Signal Cable$32.00
Click 232 Pyramid Dial Face ClockSynchronized 13" Child Clock$180.00
Click 95 Pyramid Digital ClockSynchronized 4" 4 digit clock$189.00
Click 786 Pyramid Digital Clock with SecondsSynchronized 4" 6 digit clock with seconds$219.00
Click 82 Pyramid 5300 Work Shift TimerTimer & Bell Power Booster$129.00
      

 

Pyramid 7000 scheduled workshift timer
Includes custom-made 110v-10amp protected power supply


It will be black, and slightly different inside when it is delivered to you

Master clock and bell system overview:

Single Bell Circuit, run as many bells or buzzers as needed
---  Also works with Tone Generators and PA Systems
Set up to 200 events, each event (signal) can run on multiple days
Each event can be shared across up to 7 days.
Each event can ring from .5 sec to 15 seconds. Unique to each event.
--- It will easily accommodate a 3 shift operation

No need to reset, it keeps the time when the power is off
--- and restores to the correct time when it comes back on
Automatically adjusts for daylight savings - you can turn this off.

This is an old picture, now they are black.  We've been selling (and installing) these machines since 1997.

   

110VAC upgraded Pyramid 7000 scheduled timer can control:

1) Up to 200 digital Pyramid child clocks, up to 200' away*
2) Up to 8 analog Pyramid child clocks, up to 200' away*
     * Requires Pyramid BCD signal cable and 110V at each clock location)
3) Unlimited 120VAC bells. Large installations may require inexpensive power boosters
4) Unlimited 120VAC horns/buzzers. Large installations may require inexpensive power boosters

Includes: 

  • Pyramid 7000 masterclock terminal and easy-to-understand owners manual
  • Power supply
  • Internal 110V - 10Amp mechanical relay.  Pre-wired and tested
  • 10 Amp rated 110V grounded power cord
  • Toll-Free Telephone Support
  • One year product replacement guarantee

Specifications:

  • 6" high, 5.5" wide, 2" deep
  • Requires two plugs (a duplex outlet)
  • Initial output is 24VDC, modified to 110VAC with 10Amp DPDT Mechanical Relay

Suggestions:

  • Add bright, easy-to-read digital synchronized wall clocks throughout your facility
  • The 7000 can control Pyramid digital and Pyramid analog (clock face) clocks
  • We have over 400 of these systems installed (as of August, 2016)
  • We are not copying web content to our website, we know this equipment inside and out

    We have actual installation and on-site problem solving experience
    In this business, we are unique, with hands-on experience, and that is why you should call us.

 

 

 

 

Pyramid 7000 scheduled work shift timer program example

Imagine everyone going back to work on-time at the end of breaks, end of lunch. 

We made this example, many people print it out and make their own, using this as inspiration.
Notice that there is a three-minute warning for the end of lunch.  A five-minute warning for the end of the day. 
This works.  Give it some thought.

Print this out, write up your own.  Make a short one second ring for the warnings.
Pyramid 7000 and our network bell systems do this.  The Lathem Sonachron does not.


 

Information you will not find anywhere else...

You can theoretically run 32 bells, plus 16 analog clocks, and unlimited digital clocks off of the 7000, And 32 low voltage Pyramid bells off the 5300.  It's not that easy.  So we did the research.

Pyramid digital clocks self-amplify the time signal and forward it to the next clock via the company's proprietary BCD cable.  You must have a digital clock (or a 5300 signal amplifier) every 200' for this to work. BCD cables connect with Pyramid's again propretary "Y" connector - which we will supply to you as many as you need at no charge (nickels and dimes).

Pyramid's 13" dial face "analog" clocks do not have this signal amplification feature.  So, every 200' or 8 clocks - whichever comes first - you need to add/purchase a PTR5300 power supply.  This amplifies the time signal and allows you to extend the range.

Bells:  Pyramid low voltage bells are 24VAC and draw a very small amount of amps.  Somewhere in the range of 100M/a.  1000M/a is 1 Amp.  When you hit 250' or so, and several bells, it will start to get quiet.  We now offer a power booster that you would connect inline, adding a fresh 1 amp and 24volts DC to run additional bells as needed.

Work with people who obsess over the details - so you don't have to.

Tone Generator Controller

If this is for a tone generator, we can make it cold contact instead of 110V output.  Just let us know
.